Hinged Expansion joint
Stainless Steel Hinged Expansion Joint
Application:
Absorb the angular displacement of single-plane.
Installation attention:
1.Two or three stainless steel compensator use together
2.the installation of stainless steel compensator must maintains the hinged rotation plane and the displacement plane consistent.
Construction
ITEM | PARTS | MATERIAL | REMARK |
1 | BELLOWS | SUS304 | SUS316/321 |
2 | FLANGE | SS400 | SUS304/316/321 |
3 | TUBE ENDS | SPG/SS400 | SUS304/316 |
4 | HINGED PIN | SS400 | SUS304 |
5 | HINGED ARM | SUS304 | SUS304 |
Specification
DN | TOTAL LENGTH | BELLOWS OUTSIDE DIA. | EFFECTICE AREA | ANGULAR ROTATION | MAX.WORKING PRESSURE KG/CM2 | |
mm | mm | mm | cm2 | degree | EH1600 | EH1600H |
32 | 200 | 49 | 14.5 | 20 | 10 | 16 |
40 | 200 | 58 | 17.6 | 20 | 10 | 16 |
50 | 200 | 76 | 30.4 | 20 | 10 | 16 |
65 | 250 | 92 | 43.8 | 19 | 10 | 16 |
80 | 250 | 106 | 62.8 | 19 | 10 | 16 |
100 | 250 | 133 | 107.7 | 15 | 10 | 16 |
125 | 250 | 163 | 162.9 | 13 | 10 | 16 |
150 | 250 | 190 | 227.5 | 12 | 10 | 16 |
200 | 300 | 252 | 385.3 | 12 | 10 | 16 |
250 | 350 | 315 | 670.1 | 11 | 10 | 16 |
300 | 350 | 366 | 923.5 | 10 | 10 | 16 |
350 | 350 | 398.1 | 1102 | 10 | 10 | 16 |
400 | 400 | 462.8 | 1464 | 10 | 10 | 16 |
500 | 400 | 564 | 2235 | 10 | 10 | 16 |
600 | 400 | 666 | 3167 | 10 | 10 | 16 |